l 结构合理的紧凑型加热炉,实现了高灵敏度、高性能和低噪音
l 合理结构的加热炉实现快速气体替代
l 高效的加热和冷却速率,提高了丈量效率
l 整个系统的宁静性为主
l 丈量温度规模:-150至725 ℃
l 配套冷却装置(需选配)可用温度低于情况温度
l 温度高于500 ℃时需要惰性气体填充
ASTM D3418 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry, (用差示扫描量热法测定聚合物熔融和结晶转变温度及热焓的标准测试要领)。
ASTM D3895 Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry, (用差示扫描量热法测定聚烯烃质料氧化诱导期的标准测试要领)。
ASTM D4419 Standard Test Method for Measurement of Transition Temperatures of Petroleum Waxes by Differential Scanning Calorimetry (DSC), (用差示扫描量热法丈量石油蜡转变温度的标准测试要领)。
ASTM D4591 Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry, (用差示扫描量热法测定含氟聚合物温度和转化热的标准测试要领)。
ASTM D5028 Standard Test Method for Curing Properties of Pultrusion Resins by Thermal Analysis, (用热剖析法测试挤拉树脂固化性的标准测试要领)。
ASTM E793-06 Standard Test Method for Enthalpies of Fusion and Crystallization by Differential Scanning Calorimetry, (用差示扫描量热法测定熔融和结晶焓的标准试验要领)。
ASTM E794-06 Standard Test Method for Melting And Crystallization Temperatures By Thermal Analysis, (用热剖析法丈量熔融和结晶温度的标准测试要领)。 s
ASTM E1269 Standard Test Method for Determining Specific Heat Capacity by Differential Scanning Calorimetry, (用差示扫描热量法(DSC)测定比热容量的标准试验要领)。
ASTM E1356 Standard Test Method for Assignment of the Glass Transition Temperatures by Differential Scanning Calorimetry, (用差示扫描量热法测试玻璃化转变温度的标准测试要领)。
ASTM E1782 Standard Test Method for Determining Vapor Pressure by Thermal Analysis, (用热剖析法测定蒸汽压力的标准测试要领)。
ASTM E2160 Standard Test Method for Heat of Reaction of Thermally Reactive Materials by Differential Scanning Calorimetry, (用差示扫描量热法测定热反应质料反应热的标准测试要领)。
ASTM E2716 Standard Test Method for Determining Specific Heat Capacity by Modulated Temperature Differential Scanning Calorimetry, (用正弦温度调制DSC法测定比热容的标准测试要领)。
ISO 11357-4 Plastics, Differential scanning calorimetry(DSC), Part 4: Determination of specific heat capacity, (塑料,差式扫描量热法(DSC),第4部分:比热容的测定)。
ISO 11357-3 Plastics, Differential scanning calorimetry (DSC), Part 3: Determination of temperature and enthalpy of melting and crystallization, (塑料,差示扫描量热法(DSC),第3部分:熔化和结晶温度和焓的测定)。
ISO 11357-2 Plastics, Differential scanning calorimetry (DSC), Part 2: Determination of glass transition temperature and step height, (塑料,差示扫描量热法(DSC),第2部分:玻璃化转变温度和台阶高度的测定)。
ISO 22768 Raw rubber and rubber latex, Determination of the glass transition temperature by differential scanning calorimetry (DSC), (生橡胶和橡胶胶乳,用差示扫描量热法(DSC)测定玻璃化转变温度)。
型号 | DSCvesta2 |
名称 | 差示扫描量热仪 |
技术 | 接纳差示扫描量热法,将提高样品和参比物的温度所需的热量的差别作为温度的函数进行丈量,可以视察熔融和结晶事件以及玻璃化转变温度,也可以用于研究氧化以及其他化学反应。 |
可选配 | 自动进样器(ASC),低温冷却系统(LR),循环冷却装置(-10 to 725℃),电气冷却装置(-95 to 725℃),LN2 自动填充冷却装置(-150 to 725℃),LN2 直接冷却装置(-180 to 725℃) |
盘算机 | 外部PC |
尺寸(L×D×H) | 520×210×310 mm |
重量(焦点单位) | 13.5 kg(30.5 kg,带智能装载机) |
电源功率 | AC100-120V/200-240V 50/60Hz 5A |
温度范围 | -150 to 750℃ |
大气测定温度规模 | 室温 to 500℃ |
液氮冷却 | -130 to 750℃ |
电器冷却 | Incompatible |
量程 | ±100 mW |
噪音 | <0.5 μW |
样品视察 | 不相容 |
vestaeye? | 未配备 |
加热炉 | 需工程师更换 |